F3W-D052D 1M

F3W-D052D 1M

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

  • 描述:

    PICKING SENSOR 1M

  • 数据手册
  • 价格&库存
F3W-D052D 1M 数据手册
Non Safety Picking Sensor F3W-D • Sensing distance of 3 m. • Selectable display mode (all lighting, all flashing, elevator-like lighting, accordion-like lighting). • Six picking indicators provide a very clear display. • Selectable display speed (SLOW/ FAST). • External picking indicators may be connected. • External indicators can be directly connected to the Picking Sensor and mounted in an easy-to-see location. Compact, Resistant to Mutual Interference, and Ideal for Picking a Variety of Parts Ordering Information Sensors Sensing method Appearance Connection method Sensing distance Pre-wired (5 m) Throughbeam Connector (2 m) Pre-wired (5 m) Connector (2 m) 3m Opticalaxis pitch No. of optical axes Detecting height (mm) 25 mm 5 100 Output type External indicator NPN open collector --- F3W-D052A Possible F3W-D052AP PNP open collector Model --- F3W-D052B Possible F3W-D052BP --- F3W-D052C Possible F3W-D052CP --- F3W-D052D Possible F3W-D052DP @ WARNING: F3W-D Do not apply F3W-D as safety mechanisms used in pressing machines or any other safety mechanisms for protecting the human body from danger F3W-D G-371 Accessories (Sold Separately) Mounting Brackets Appearance Model Quantity Remarks Y-shaped Joint Plugs and Sockets (Double-ended Connectors) Appearance F39-L10 2 Overall length 2m L-shaped Mounting Bracket Model XS2R-D526S001-2 Quantity 1 XS2R-D526S001-5 5m 1 Y-shaped Joint Plugs and Sockets without Cable F39-L11 2 Flat Mounting Bracket Protective Bracket Appearance Model F39-L12 G-372 Quantity One each for Emitter and Receiver (mounting screws included) Appearance Model Quantity XS2R-D526S003 1 Remarks Connecting cable: Double-ended connector: XS2W Series Single-ended connector: XS2F-series 4conductor models Safety Sensors / Components Specifications Ratings / Characteristics PNP Output Item Sensing distance Optical-axis pitch No. of optical axes Detecting height Sensing object Light source (wavelength) Power supply voltage Power consumption Control output Picking instruction indicator input Protection circuit Response time Receiver Indicator Emitter Ambient temperature Ambient humidity Insulation resistance Dielectric strength Vibration resistance Shock resistance Degree of protection Connection method Weight (including package) Case, display window Materials Lens Operation cover Accessories Through-beam F3W-D052C(P) (see note 1) F3W-D052D(P) (see note 1) 3 m, switchable between LONG mode (1 to 3 m) and SHORT mode: (0.05 to 1 m), factory-set to SHORT mode 25 mm 5 100 mm Opaque, 35 mm dia. min., Infrared LED (860 nm) 12 to 24 VDC±10% (ripple range (p-p): 10% max.) Emitter: 0.6 W max., Receiver: 0.7 W max. PNP open collector with 100 mA max. at 30 VDC Residual voltage: 2,5 V max. at 100 mA Dark ON or Light ON (selectable) Open collector with relay or transistor input Indicator ON: Input voltage of 0 to 2 V Indicator OFF: Open (with leakage current of 0.1 mA max.) Reverse-connection protection, output short protection, and mutual interference interrupting function (set with frequency selector switch) Operate/Release: 10 ms max. Operation indicator (orange), stability indicator (green), and 6 picking indicators (orange) Power indicator (green), different frequency indicator (green), and 6 picking indicators (orange) Operating: -10° to 55°C Storage: -25° to 70°C (with no icing or condensation) 35 to 85% (with no condensation) 20 M min. (at 500 VDC) 1,000 VAC 50/60 Hz for 1 min Destruction: 10 to 50 Hz, 1.5-mm double-amplitude for 2 hours each in X, Y and Z directions Destruction: 500 m/s2, 3 times each in X, Y and Z directions IEC60529: IP62 (with the operation cover closed) Pre-wired Connector (M12 5-pin connector) Standard cable length: 5 m Standard cable length: 2 m Approx. 360 g Approx. 230 g ABS resin Acrylic resin Nylon (PA6) Instruction manual Note: 1 . The F3W-D052@P Emitters are provided with the external picking indicator output line shown in the following table.I Item Connection method F3W-D Electrical specifications F3W-D052CP, F3W-D052DP Pre-wired with connector (standard cable length: 300 mm) Connector model: SMP-02V-NC (manufactured by Nihon Crimp Terminal, Ltd.) Output current: 50 mA max. Output voltage: Fixed at sensor power supply voltage F3W-D G-373 NPN Output Item Sensing distance Optical-axis pitch No. of optical axes Detecting height Sensing object Light source (wavelength) Power supply voltage Power consumption Control output Picking instruction indicator input Protection circuit Response time Receiver Indicator Emitter Ambient temperature Ambient humidity Insulation resistance Dielectric strength Vibration resistance Shock resistance Degree of protection Connection method Weight (including package) Case, display window Materials Lens Operation cover Accessories Through-beam F3W-D052A(P) (see note 1) F3W-D052B(P) (see note 1) 3 m, switchable between LONG mode (1 to 3 m) and SHORT mode: (0.05 to 1 m), factory-set to SHORT mode 25 mm 5 100 mm Opaque, 35 mm dia. min., Infrared LED (860 nm) 12 to 24 VDC±10% (ripple range (p-p): 10% max.) Emitter: 0.6 W max., Receiver: 0.7 W max. NPN open collector with 100 mA max. at 30 VDC Residual voltage: 1 V max. at 100 mA Dark ON or Light ON (selectable) Open collector with relay or transistor input Indicator ON: Input voltage of 0 to 2 V Indicator OFF: Open (with leakage current of 0.1 mA max.) Reverse-connection protection, output short protection, and mutual interference interrupting function (set with frequency selector switch) Operate/Release: 10 ms max. Operation indicator (orange), stability indicator (green), and 6 picking indicators (orange) Power indicator (green), different frequency indicator (green), and 6 picking indicators (orange) Operating: -10° to 55°C Storage: -25° to 70°C (with no icing or condensation) 35 to 85% (with no condensation) 20 M min. (at 500 VDC) 1,000 VAC 50/60 Hz for 1 min Destruction: 10 to 50 Hz, 1.5-mm double-amplitude for 2 hours each in X, Y and Z directions Destruction: 500 m/s2, 3 times each in X, Y and Z directions IEC60529: IP62 (with the operation cover closed) Pre-wired Connector (M12 5-pin connector) Standard cable length: 5 m (see note 2) Standard cable length: 2 m (see note 2) Approx. 360 g Approx. 230 g ABS resin Acrylic resin Nylon (PA6) Instruction manual Note: 1 . The F3W-D052@P Emitters are provided with the external picking indicator output line shown in the following table.I Item Connection method Electrical specifications F3W-D052AP, F3W-D052BP Pre-wired with connector (standard cable length: 300 mm) Connector model: SMP-02V-NC (manufactured by Nihon Crimp Terminal, Ltd.) Output current: 50 mA max. Output voltage: Fixed at sensor power supply voltage 2 . The following cable lengths are also available. F3W-D052A(P): 2 m, 7 m F3W-D052B(P): 1 m, 3.5 m G-374 Safety Sensors / Components Angle Characteristics (Typical) LONG Mode LONG Mode: Direction of Swing LONG Mode: Direction of Rotation Angleq (˚) Parallel operating range Y (mm) Parallel Operating Range (Typical) Angleq (˚) Engineering Data (1) (2) (2) (1) Sensing distance X (m) SHORT Mode (2) Sensing distance X (m) SHORT Mode: Direction of Rotation Angleq (˚) SHORT Mode: Direction of Swing (1) (1) Sensing distance X (m) Angleq (˚) Parallel operating range Y (mm) (2) (2) (2) (1) (1) Sensing distance X (m) Sensing distance X (m) Sensing distance X (m) (1) Emitter Angle Characteristics (1) Horizontal Movement Characteristics or (Direction of swing) (2) Vertical Movement Characteristics (Direction of rotation) (2) Receiver Angle Characteristics or F3W-D (Direction of swing) (Direction of rotation) F3W-D G-375 Nomenclature NPN Open Collector Output Models Picking indicator (orange) Detection side G-376 F3W-D052A(P)-L F3W-D052B(P)-L F3W-D052A(P)-D F3W-D052B(P)-D PNP Open Collector Output Models DIP switch 1 mode setting switch Different frequency indicator (green) Receiver Operation cover Operation cover Power indicator (green) Emitter Operation indicator (orange) Emitter Receiver F3W-D052C(P)-L F3W-D052D(P)-L F3W-D052C(P)-D F3W-D052D(P)-D Stability indicator (green) Safety Sensors / Components Operation Output Circuits NPN Output form Model State of output transistor NPN open collector output F3W-D052A, F3W-D052AP, F3W-D052B, F3W-D052BP Dark-ON mode Light-ON mode ON: One optical axis or more is interrupted ON: No optical axis is interrupted OFF: No optical axis is interrupted OFF: One optical axis or more is interrupted Light incident Timing chart No optical axis is interrupted No optical axis is interrupted One optical axis or more is interrupted ON Operation indicator (orange) OFF ON Control output Load (relay, etc.) Mode Selector Light incident One optical axis or more is interrupted ON Operation indicator (orange) OFF OFF Control output ON OFF Operate Release Load (relay, etc.) Operate Release D.ON (Dark-ON) L.ON (Light-ON) F3W-D052Aj-L/Bj-L Six Different picking Power frequency indicators indicator indicator (orange) (green) (green) F3W-D052Aj-D/Bj-D Orange/ purple stripe Six Stability Operation picking indicator indicator indicators (green) (orange) (orange) Orange/ purple stripe (Sync line) Brown 12 to 24 VDC Emitter main circuit External picking indicator output Brown Output circuit Brown Load (Control output) Black Receiver main circuit 100 mA max. Pink Load Pink Picking indicator input 50 mA max. Blue Blue Blue *1 The sections surrounded by single-dashed lines are applicable to the F3W-D052AP-L/BP-L only. *2 The circled numbers represent external picking indicator output pin numbers for a connector relay type. The following diagram shows the relationship between picking instruction input, picking indicator status, and external picking indicator output. DIP switch 1 is used to switch the picking display mode between all lighting, all flashing, elevator-like lighting, and accordion-like lighting. It is also possible to switch the external picking display mode between lighting and flashing. Picking instruction Open input 0V Picking indicator F3W-D External picking indicator output ON OFF ON OFF F3W-D G-377 Output Circuits PNP Output form Model State of output transistor PNP open collector output F3W-D052C, F3W-D052CP, F3W-D052D, F3W-D052DP Dark-ON mode Light-ON mode ON: One optical axis or more is interrupted ON: No optical axis is interrupted OFF: No optical axis is interrupted OFF: One optical axis or more is interrupted Light incident Timing chart No optical axis is interrupted One optical axis or more is interrupted ON Operation indicator (orange) OFF Control output Load (relay, etc.) Mode Selector D.ON (Dark-ON) Light incident No optical axis is interrupted One optical axis or more is interrupted ON Operation indicator (orange) OFF ON OFF Control output ON OFF Operate Release Load (relay, etc.) Operate Release L.ON (Light-ON) Output circuit G-378 Safety Sensors / Components Dimensions F3WD Emitter F3W-D052A(P)-L F3W-D052B(P)-L F3W-D052C(P)-L F3W-D052D(P)-L 2 poles Vinyl-insulated round cable, 4 dia. Standard length: 0.3 m Two, M4 nut holes (Depth: 1 mm) Six picking indicators (orange) Two, 4.5 dia Two, M4 nut holes (Depth: 3.5 mm) Mounting Hole Dimensions Two, M4 holes Five lenses, 6.5 dia. Five optical axes F3W-D052B(P)-L: Vinyl-insulated round cable, 4 dia. Standard length: 2 m Five poles 14.9 dia. F3W-D052A(P)-L:. Power indicator (green) Vinyl-insulated round cable with Different frequency four conductors, 4 dia. indicator (green) Conductor: 0.2 mm2 Insulation: 1.1 mm dia. Standard length: 5 m Receiver F3W-D052A(P)-D F3W-D052B(P)-D F3W-D052C(P)-D F3W-D052D(P)-D Two, M4 nut holes (Depth: 1 mm) Two, 4.5 dia Two, M4 nut holes (Depth: 3.5 mm) Mounting Hole Dimensions Six picking indicators (orange) Two, M4 holes Five lenses, 6.5 dia. Five optical axes Five poles F3W-D052A(P)-D. Vinyl -insulated round cable with five conductors, 4 dia. Conductor: 0.2 mm2 Insulation: 1.1 mm dia. Standard length: 5 m Operation indicator (orange) Stability indicator (green) F3W-D F3W-D052B(P)-D: Vinyl-insulated round cable, 4 dia. Standard length: 2 m 14.9 dia. Note: All units are in millimeters unless otherwise indicated F3W-D G-379 Accessories (Sold Separately) Mounting Brackets F39-L10 (L-shaped) F3W-D052A-D with Mounting Bracket Four mounting holes Material: Steel (Thickness: 2 mm) Mounting screws provided Four, 4.8 dia. Five optical axes F3W-D052A-D with Mounting Bracket F39-L11 (Flat) Four mounting holes Material: Steel (Thickness: 2 mm) Four, 4.8 dia. Five optical axes Mounting screws provided G-380 Safety Sensors / Components Protective Bracket F39-L12 (Receiver) Five, 10 dia. Two, Material: Steel (Thickness: 1.6 mm) Mounting screws provided Note: The Emitter and Receiver are axially symmetrical. Y-shaped Joint Plugs and Sockets (Double-ended Connectors) XS2R-D526-S001-2 (L=2,000 mm) XS2R-D526-S001-5 (L=5,000 mm) 4.6 dia Blue marking Y-shaped Joint Plugs and Sockets without cable XS2R-D526-S003 4.5 d F3W-D Blue mar F3W-D G-381 Precautions @ Warning: Do not apply the F3W-D as safety mechanisms used in pressing machines or any other safety mechanisms for protecting the human body from danger. 1. Do not apply the F3W-D as safety mechanisms used in pressing machines, shears, rolling machines, spinning machines, cotton mill machines, or robots for the protection of an operator’s hands and body 2. The F3W-D is designed for detection of the human body or moving objects in the detection area but not for protection against danger. 3. The F3W-D or any product incorporating the F3W-D may be exported to any country. Should the F3W-D cause any problem conflicting with the local law or related to product liability locally, however, OMRON shall, without exception, assume no responsibility for it. @ Caution Before using more than one F3W-D Unit in parallel or serial, take necessary countermeasures against mutual interference so that the unit will not malfunction. Refer to Mutual Interference Attenuating Function. General Precautions Supply Voltage Make sure that the supply voltage is within the rated range. If the supply voltage is not within the rated range or 100 VAC is imposed on a DC Sensor model, the Sensor may be damaged or malfunction. Load Short-circuiting Do not short-circuit the load, otherwise the Sensor may be damaged or malfunction. Incorrect Wiring Do not make mistakes in the polarity of power supply or wiring, otherwise the Sensor may be damaged or malfunction. Connection without Load Make sure that the load is connected to the Sensor in operation, otherwise the Sensor may be damaged or malfunction. Operating Environment Do not use the Sensor in an environment containing flammable or explosive gases. Do not use the Sensor underwater. Do not disassemble, repair, or modify the Sensor. Always turn OFF the system power before installing or replacing the Sensor. G-382 System Design Cables For both pre-wired and connector models, the maximum tensile force of cables must be 50 N. Wiring If the Sensor cables are housed in the same conduit or duct as for high-voltage and power lines, the Sensor may be subject to induced current, resulting in malfunction or damage. For this reason, the Sensor cables must be separated from the high-voltage and power lines or housed in a separate conduit. Power ON Timing It takes 100 ms for the Sensor to operate properly after it is turned ON. Therefore, other devices should be turned ON at least 100 ms after the Sensor is turned ON. If the Sensor and the load are connected to different power supplies, the Sensor power must be turned ON first. Power Supply When using a commercially available switching regulator, always ground it to the frame ground (FG) or ground (G) terminal. Otherwise, switching noise may result in malfunctions. Mutual Interference Attenuating Function 1. Two Sets of Sensors: Set these Sensors to different frequencies with the frequency selector. Refer to DIP Switch 1 Mode Switching later in this datasheet. If the mutual interference attenuating function is not used, and there are two Sensors with the same frequency setting, a beam from the Emitter of one Sensor may hit the Receiver of the other Sensor, resulting in malfunction. This function cannot prevent mutual interference between the F3W-D Sensor and a Photoelectric Sensor of another model. 2. Three or More Sets of Sensors: When 3 or more sets of Sensors are used in parallel, mutual interference may result in malfunction. Take the following measures to prevent mutual interference, and check for mutual interference. • While in LONG mode, the Sensors are more easily affected by interference. Therefore, if the distance between the Emitter and Receiver of a Sensor is 1 m or less, use the SHORT mode. • The distance between two adjacent sets of Sensors must be at least l1 or l2, which does not cause mutual interference between two Sensors with the same frequency setting. l1 or l2 is at least 1.5 times the distance shown in Parallel Operating Range of the Engineering Data. Safety Sensors / Components Receivers Vertical Installation Emitter Horizontal Installation Receiver Emitter Receiver DIP switch 1 1 2 Emitter 2 Receiver Distance X Emitter 1 Receiver Distance X • Install a barrier so that there will not be mutual interference between Sensors with the same frequency setting. (See Figure 1.) A light reflection from the wall or floor may go around a barrier and reach the Receivers. Install a barrier so that it will also block any light reflection. (See Figure 2.) Figure 1 Emitter Figure 2 Receiver Correct Emitter OFF (left) (See note 3.) 3 Picking indicator flash- SLOW ing speed setting (see note 1) FAST 4 Output mode setting Light-ON 5 Sensing distance (sen- LONG SHORT sitivity) setting mode (1 to mode (0.05 3 m) to 1 m) 6 Not used Emitter Receiver Emitter DIP switch 1 Pin 1 Pin 2 OFF OFF ON OFF Display mode All lighting (All six indicators are lit.) OFF Emitter ON Receiver All flashing Emitter Elevator-like lighting (Two adjacent indicators simultaneously light so that lighting moves up and down.) ON Wall Receiver --- Note: 1 . The flashing speed can be changed in picking display mode (all flashing, elevator-like lighting, or accordion-like lighting) or in external picking display mode. The flashing speed varies with each display mode. 2 . Mutual Interruption Attenuating Function: The frequency selector is used to switch the emitting frequency between A and B. Making the emitting frequencies of two Sensors different prevents malfunction caused by mutual interference. 3 . Picking Display Mode Setting of DIP Switch 1 ON Incorrect Dark-ON --- Baffle Baffle ON (right) (All six indicators flash simultaneously.) Wall Receiver Function Picking display mode setting Accordion-like lighting (Some or all indicators simultaneously light so that lighting moves like an accordion.) Receiver Elevator-like Lighting Mode Baffle Display progress Not lit Lit Correct Use DIP Switch 1 Mode Switching Emitters 1 2 Function OFF (left) Picking display mode setting (See note 3.) Accordion-like Lighting Mode Display progress 3 Picking indicator flash- SLOW ing speed setting (see note 1) FAST 4 External picking display mode setting (see note 4) Flashing Lit 4 . For F3W-D052jP-L Emitters only 5 NC --- 6 Frequency setting Frequency Frequency A B (see note 2) F3W-D ON (right) --- Wiring Before turning ON the power, make sure that the supply voltage is within the maximum allowable voltage range. Always connect the sync lines. Extension cables must be 0.3 mm2 or more in cross-sectional area and 100 m or less in length (for the F3W-D052A(P) and F3W-D052B(P) only). Be very careful not to get metal chips in the connector especially during wiring. Incorrect wiring may damage the equipment. Make sure that the cable length and routing are appropriate to prevent the connectors and cables from getting disconnected. G-383 F3W-D DIP switch 1 Always leave the operation cover closed during operation. Applying excessive force to the mode selector switch may result in damage. Do not apply a force of more than 5 N. Cables Make sure that the bending radius is 25 mm or more. Installation Install the Sensor so that its sensing face will not receive light from the sun, fluorescent lamps, incandescent lamps, and other light sources. Do not strike the Sensor with a hammer or any other tool during the installation, otherwise the internal circuitry of the Sensor may be damaged. Install the Emitter and Receiver in the same orientation as shown in the following figure. (The cable pullout direction must be the same.) Correct Emitter Incorrect Receiver Emitter Receiver Use M4 screws to secure the Sensor body. Secure the case to a tightening torque of 1.2 N×m or less. Reflection from Wall or Floor If the Emitter and Receiver are installed as shown in the following illustration, all the axes may not be interrupted due to light reflection from the floor or wall. Make sure that the Emitter and Receiver detect the sensing object properly before using the F3W-D in actual operation. Side View Operation and Stability Status Display The following illustration shows the indicator status corresponding to each incident level. Install the Receiver so that the green stability indicators are both ON in light receiving status. Stability indi cator (green) Amount of light received Stable light-re ceiving zone (see note) Unstable light-receiv ing zone Light-shielded zone Operation indicator (orange) L-ON D-ON ON OFF OFF ON ON Operating level x 1.2 Operating level OFF Note: If the Receiver is set to the stable light-receiving zone, it will become more resistant to environmental fluctuations such as temperature, voltage, dust, and setting deviation after installation. For applications where a stable light-receiving zone is not obtained, attention must be paid to environmental fluctuations. Installation Environment Do not install the F3W-D Sensor under the following conditions. · Where direct sunlight is received · Where humidity is high and there is a risk of condensation · Where there are corrosive gases · Where vibration and shock are directly transmitted to the Sensor Cleaning · Do not use organic solvents for cleaning. Otherwise, the surfaces of the Sensor will be eroded. · Use a soft, dry cleaning cloth. Top View Wall Sensing object Floor Emitter Receiver Light reflection M12 Connectors Always turn OFF the power before connecting or disconnecting an M12 connector. Always connect or disconnect an M12 connector by holding its cover. Always tighten the fixture by hand. Using pliers may result in damage. Insufficient tightening may loosen the connector due to vibration, resulting in failure to ensure the specified degree of protection. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. F048-E2-01-X G-384 In the interest of product improvement, specifications are subject to change without notice. Safety Sensors / Components Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS, OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the product. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: • Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. • Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. • Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased product. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. ERRORS AND OMISSIONS The information in this catalog has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. COPYRIGHT AND COPY PERMISSION This catalog shall not be copied for sales or promotions without permission. This catalog is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or reproducing this catalog in any manner, for any other purpose. If copying or transmitting this catalog to another, please copy or transmit it in its entirety. Cat. No. F048-E2-01-X OMRON Corporation 2007. 3 In the interest of product improvement, specifications are subject to change without notice. Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved.
F3W-D052D 1M 价格&库存

很抱歉,暂时无法提供与“F3W-D052D 1M”相匹配的价格&库存,您可以联系我们找货

免费人工找货