Non Safety Picking Sensor
F3W-D
• Sensing distance of 3 m.
• Selectable display mode (all lighting, all
flashing, elevator-like lighting, accordion-like lighting).
• Six picking indicators provide a very
clear display.
• Selectable display speed (SLOW/
FAST).
• External picking indicators may be connected.
• External indicators can be directly connected to the Picking Sensor and
mounted in an easy-to-see location.
Compact, Resistant to Mutual Interference,
and Ideal for Picking a Variety of Parts
Ordering Information
Sensors
Sensing
method
Appearance
Connection
method
Sensing distance
Pre-wired
(5 m)
Throughbeam
Connector
(2 m)
Pre-wired
(5 m)
Connector
(2 m)
3m
Opticalaxis pitch
No. of
optical
axes
Detecting
height
(mm)
25 mm
5
100
Output
type
External indicator
NPN
open
collector
---
F3W-D052A
Possible
F3W-D052AP
PNP
open
collector
Model
---
F3W-D052B
Possible
F3W-D052BP
---
F3W-D052C
Possible
F3W-D052CP
---
F3W-D052D
Possible
F3W-D052DP
@ WARNING:
F3W-D
Do not apply F3W-D as safety mechanisms used in pressing machines or any other safety mechanisms for
protecting the human body from danger
F3W-D
G-371
Accessories (Sold Separately)
Mounting Brackets
Appearance
Model
Quantity
Remarks
Y-shaped Joint Plugs and Sockets
(Double-ended Connectors)
Appearance
F39-L10
2
Overall length
2m
L-shaped
Mounting
Bracket
Model
XS2R-D526S001-2
Quantity
1
XS2R-D526S001-5
5m
1
Y-shaped Joint Plugs and Sockets without Cable
F39-L11
2
Flat Mounting
Bracket
Protective Bracket
Appearance
Model
F39-L12
G-372
Quantity
One each for Emitter and Receiver (mounting screws included)
Appearance
Model
Quantity
XS2R-D526S003
1
Remarks
Connecting cable:
Double-ended
connector:
XS2W Series
Single-ended
connector:
XS2F-series 4conductor models
Safety Sensors / Components
Specifications
Ratings / Characteristics
PNP Output
Item
Sensing distance
Optical-axis pitch
No. of optical axes
Detecting height
Sensing object
Light source (wavelength)
Power supply voltage
Power consumption
Control output
Picking instruction indicator input
Protection circuit
Response time
Receiver
Indicator
Emitter
Ambient temperature
Ambient humidity
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Degree of protection
Connection method
Weight (including package)
Case, display window
Materials
Lens
Operation cover
Accessories
Through-beam
F3W-D052C(P) (see note 1)
F3W-D052D(P) (see note 1)
3 m, switchable between LONG mode (1 to 3 m) and SHORT mode: (0.05 to 1 m),
factory-set to SHORT mode
25 mm
5
100 mm
Opaque, 35 mm dia. min.,
Infrared LED (860 nm)
12 to 24 VDC±10% (ripple range (p-p): 10% max.)
Emitter:
0.6 W max.,
Receiver:
0.7 W max.
PNP open collector with 100 mA max. at 30 VDC
Residual voltage: 2,5 V max. at 100 mA
Dark ON or Light ON (selectable)
Open collector with relay or transistor input
Indicator ON: Input voltage of 0 to 2 V
Indicator OFF: Open
(with leakage current of 0.1 mA max.)
Reverse-connection protection, output short protection, and mutual interference interrupting function (set with frequency selector switch)
Operate/Release: 10 ms max.
Operation indicator (orange), stability indicator (green), and 6 picking indicators (orange)
Power indicator (green), different frequency indicator (green), and 6 picking indicators (orange)
Operating:
-10° to 55°C
Storage:
-25° to 70°C (with no icing or condensation)
35 to 85% (with no condensation)
20 M min. (at 500 VDC)
1,000 VAC 50/60 Hz for 1 min
Destruction: 10 to 50 Hz, 1.5-mm double-amplitude for 2 hours each in X, Y and Z directions
Destruction: 500 m/s2, 3 times each in X, Y and Z directions
IEC60529: IP62 (with the operation cover closed)
Pre-wired
Connector (M12 5-pin connector)
Standard cable length: 5 m
Standard cable length: 2 m
Approx. 360 g
Approx. 230 g
ABS resin
Acrylic resin
Nylon (PA6)
Instruction manual
Note: 1 . The F3W-D052@P Emitters are provided with the external picking indicator output line shown in the following table.I
Item
Connection method
F3W-D
Electrical specifications
F3W-D052CP, F3W-D052DP
Pre-wired with connector (standard cable length: 300 mm)
Connector model: SMP-02V-NC (manufactured by Nihon Crimp Terminal, Ltd.)
Output current:
50 mA max.
Output voltage:
Fixed at sensor power supply voltage
F3W-D
G-373
NPN Output
Item
Sensing distance
Optical-axis pitch
No. of optical axes
Detecting height
Sensing object
Light source (wavelength)
Power supply voltage
Power consumption
Control output
Picking instruction indicator input
Protection circuit
Response time
Receiver
Indicator
Emitter
Ambient temperature
Ambient humidity
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Degree of protection
Connection method
Weight (including package)
Case, display window
Materials
Lens
Operation cover
Accessories
Through-beam
F3W-D052A(P) (see note 1)
F3W-D052B(P) (see note 1)
3 m, switchable between LONG mode (1 to 3 m) and SHORT mode: (0.05 to 1 m),
factory-set to SHORT mode
25 mm
5
100 mm
Opaque, 35 mm dia. min.,
Infrared LED (860 nm)
12 to 24 VDC±10% (ripple range (p-p): 10% max.)
Emitter:
0.6 W max.,
Receiver:
0.7 W max.
NPN open collector with 100 mA max. at 30 VDC
Residual voltage: 1 V max. at 100 mA
Dark ON or Light ON (selectable)
Open collector with relay or transistor input
Indicator ON: Input voltage of 0 to 2 V
Indicator OFF: Open
(with leakage current of 0.1 mA max.)
Reverse-connection protection, output short protection, and mutual interference interrupting function (set with frequency selector switch)
Operate/Release: 10 ms max.
Operation indicator (orange), stability indicator (green), and 6 picking indicators (orange)
Power indicator (green), different frequency indicator (green), and 6 picking indicators (orange)
Operating:
-10° to 55°C
Storage:
-25° to 70°C (with no icing or condensation)
35 to 85% (with no condensation)
20 M min. (at 500 VDC)
1,000 VAC 50/60 Hz for 1 min
Destruction: 10 to 50 Hz, 1.5-mm double-amplitude for 2 hours each in X, Y and Z directions
Destruction: 500 m/s2, 3 times each in X, Y and Z directions
IEC60529: IP62 (with the operation cover closed)
Pre-wired
Connector (M12 5-pin connector)
Standard cable length: 5 m (see note 2)
Standard cable length: 2 m (see note 2)
Approx. 360 g
Approx. 230 g
ABS resin
Acrylic resin
Nylon (PA6)
Instruction manual
Note: 1 . The F3W-D052@P Emitters are provided with the external picking indicator output line shown in the following table.I
Item
Connection method
Electrical specifications
F3W-D052AP, F3W-D052BP
Pre-wired with connector (standard cable length: 300 mm)
Connector model: SMP-02V-NC (manufactured by Nihon Crimp Terminal, Ltd.)
Output current:
50 mA max.
Output voltage:
Fixed at sensor power supply voltage
2 . The following cable lengths are also available.
F3W-D052A(P): 2 m, 7 m
F3W-D052B(P): 1 m, 3.5 m
G-374
Safety Sensors / Components
Angle Characteristics
(Typical)
LONG Mode
LONG Mode: Direction of Swing
LONG Mode: Direction of Rotation
Angleq (˚)
Parallel operating range Y (mm)
Parallel Operating Range
(Typical)
Angleq (˚)
Engineering Data
(1)
(2)
(2)
(1)
Sensing distance X (m)
SHORT Mode
(2)
Sensing distance X (m)
SHORT Mode: Direction of Rotation
Angleq (˚)
SHORT Mode: Direction of Swing
(1)
(1)
Sensing distance X (m)
Angleq (˚)
Parallel operating range Y (mm)
(2)
(2)
(2)
(1)
(1)
Sensing distance X (m)
Sensing distance X (m)
Sensing distance X (m)
(1) Emitter Angle Characteristics
(1) Horizontal Movement Characteristics
or
(Direction of swing)
(2) Vertical Movement Characteristics
(Direction of rotation)
(2) Receiver Angle Characteristics
or
F3W-D
(Direction of swing) (Direction of rotation)
F3W-D
G-375
Nomenclature
NPN Open Collector Output Models
Picking indicator
(orange)
Detection side
G-376
F3W-D052A(P)-L
F3W-D052B(P)-L
F3W-D052A(P)-D
F3W-D052B(P)-D
PNP Open Collector Output Models
DIP switch 1
mode setting
switch
Different
frequency
indicator
(green)
Receiver
Operation cover
Operation cover
Power
indicator
(green)
Emitter
Operation
indicator
(orange)
Emitter
Receiver
F3W-D052C(P)-L
F3W-D052D(P)-L
F3W-D052C(P)-D
F3W-D052D(P)-D
Stability
indicator
(green)
Safety Sensors / Components
Operation
Output Circuits NPN
Output form
Model
State of output transistor
NPN open collector output
F3W-D052A, F3W-D052AP, F3W-D052B, F3W-D052BP
Dark-ON mode
Light-ON mode
ON:
One optical axis or more is interrupted
ON:
No optical axis is interrupted
OFF: No optical axis is interrupted
OFF: One optical axis or more is interrupted
Light
incident
Timing chart
No optical axis is interrupted
No optical axis is interrupted
One optical axis or more is
interrupted
ON
Operation indicator (orange)
OFF
ON
Control output
Load (relay, etc.)
Mode Selector
Light
incident
One optical axis or more is
interrupted
ON
Operation indicator (orange)
OFF
OFF
Control output
ON
OFF
Operate
Release
Load (relay, etc.)
Operate
Release
D.ON (Dark-ON)
L.ON (Light-ON)
F3W-D052Aj-L/Bj-L
Six
Different
picking
Power frequency
indicators indicator indicator
(orange) (green) (green)
F3W-D052Aj-D/Bj-D
Orange/
purple stripe
Six
Stability Operation picking
indicator indicator indicators
(green) (orange) (orange)
Orange/
purple stripe
(Sync line)
Brown
12 to
24 VDC
Emitter
main
circuit
External picking
indicator output
Brown
Output circuit
Brown
Load
(Control
output)
Black
Receiver
main
circuit
100 mA max.
Pink
Load
Pink
Picking
indicator
input
50 mA max.
Blue
Blue
Blue
*1 The sections surrounded by single-dashed lines are applicable to the F3W-D052AP-L/BP-L only.
*2 The circled numbers represent external picking indicator output pin numbers for a connector relay type.
The following diagram shows the relationship between picking instruction input, picking indicator status, and external picking indicator output.
DIP switch 1 is used to switch the picking display mode between all lighting, all flashing, elevator-like lighting, and accordion-like lighting.
It is also possible to switch the external picking display mode between lighting and flashing.
Picking instruction Open
input
0V
Picking indicator
F3W-D
External picking
indicator output
ON
OFF
ON
OFF
F3W-D
G-377
Output Circuits PNP
Output form
Model
State of output transistor
PNP open collector output
F3W-D052C, F3W-D052CP, F3W-D052D, F3W-D052DP
Dark-ON mode
Light-ON mode
ON:
One optical axis or more is interrupted
ON:
No optical axis is interrupted
OFF: No optical axis is interrupted
OFF: One optical axis or more is interrupted
Light
incident
Timing chart
No optical axis is interrupted
One optical axis or more is
interrupted
ON
Operation indicator (orange)
OFF
Control output
Load (relay, etc.)
Mode Selector
D.ON (Dark-ON)
Light
incident
No optical axis is interrupted
One optical axis or more is
interrupted
ON
Operation indicator (orange)
OFF
ON
OFF
Control output
ON
OFF
Operate
Release
Load (relay, etc.)
Operate
Release
L.ON (Light-ON)
Output circuit
G-378
Safety Sensors / Components
Dimensions
F3WD
Emitter
F3W-D052A(P)-L
F3W-D052B(P)-L
F3W-D052C(P)-L
F3W-D052D(P)-L
2 poles
Vinyl-insulated round cable, 4 dia.
Standard length: 0.3 m
Two, M4 nut holes
(Depth: 1 mm)
Six picking indicators (orange)
Two, 4.5 dia
Two, M4 nut holes
(Depth: 3.5 mm)
Mounting Hole Dimensions
Two, M4 holes
Five lenses,
6.5 dia.
Five
optical
axes
F3W-D052B(P)-L:
Vinyl-insulated round
cable, 4 dia.
Standard length: 2 m
Five poles
14.9 dia.
F3W-D052A(P)-L:.
Power indicator (green)
Vinyl-insulated round cable with
Different frequency
four conductors, 4 dia.
indicator (green)
Conductor: 0.2 mm2
Insulation: 1.1 mm dia.
Standard length: 5 m
Receiver
F3W-D052A(P)-D
F3W-D052B(P)-D
F3W-D052C(P)-D
F3W-D052D(P)-D
Two, M4 nut
holes
(Depth: 1 mm)
Two, 4.5 dia
Two, M4 nut holes
(Depth: 3.5 mm)
Mounting Hole Dimensions
Six picking indicators
(orange)
Two, M4 holes
Five lenses,
6.5 dia.
Five
optical
axes
Five poles
F3W-D052A(P)-D.
Vinyl -insulated round cable
with five conductors, 4 dia.
Conductor: 0.2 mm2
Insulation: 1.1 mm dia.
Standard length: 5 m
Operation indicator (orange)
Stability indicator (green)
F3W-D
F3W-D052B(P)-D:
Vinyl-insulated round
cable, 4 dia.
Standard length: 2 m
14.9 dia.
Note: All units are in millimeters unless otherwise indicated
F3W-D
G-379
Accessories (Sold Separately)
Mounting Brackets
F39-L10 (L-shaped)
F3W-D052A-D with Mounting Bracket
Four
mounting
holes
Material: Steel (Thickness: 2 mm)
Mounting screws provided
Four, 4.8 dia.
Five
optical
axes
F3W-D052A-D with Mounting Bracket
F39-L11 (Flat)
Four
mounting
holes
Material: Steel (Thickness: 2 mm)
Four, 4.8 dia.
Five optical
axes
Mounting screws provided
G-380
Safety Sensors / Components
Protective Bracket
F39-L12 (Receiver)
Five, 10 dia.
Two,
Material: Steel (Thickness: 1.6 mm)
Mounting screws provided
Note: The Emitter and Receiver are axially symmetrical.
Y-shaped Joint Plugs and Sockets (Double-ended Connectors)
XS2R-D526-S001-2 (L=2,000 mm)
XS2R-D526-S001-5 (L=5,000 mm)
4.6 dia
Blue marking
Y-shaped Joint Plugs and Sockets without cable
XS2R-D526-S003
4.5 d
F3W-D
Blue mar
F3W-D
G-381
Precautions
@ Warning:
Do not apply the F3W-D as safety mechanisms
used in pressing machines or any other safety
mechanisms for protecting the human body from
danger.
1. Do not apply the F3W-D as safety mechanisms used
in pressing machines, shears, rolling machines, spinning machines, cotton mill machines, or robots for
the protection of an operator’s hands and body
2. The F3W-D is designed for detection of the human
body or moving objects in the detection area but not
for protection against danger.
3. The F3W-D or any product incorporating the F3W-D
may be exported to any country. Should the F3W-D
cause any problem conflicting with the local law or related to product liability locally, however, OMRON
shall, without exception, assume no responsibility for
it.
@ Caution
Before using more than one F3W-D Unit in parallel or serial, take necessary countermeasures against mutual interference so that the unit will not malfunction. Refer to
Mutual Interference Attenuating Function.
General Precautions
Supply Voltage
Make sure that the supply voltage is within the rated range. If
the supply voltage is not within the rated range or 100 VAC is
imposed on a DC Sensor model, the Sensor may be damaged
or malfunction.
Load Short-circuiting
Do not short-circuit the load, otherwise the Sensor may be
damaged or malfunction.
Incorrect Wiring
Do not make mistakes in the polarity of power supply or wiring, otherwise the Sensor may be damaged or malfunction.
Connection without Load
Make sure that the load is connected to the Sensor in operation, otherwise the Sensor may be damaged or malfunction.
Operating Environment
Do not use the Sensor in an environment containing flammable or explosive gases.
Do not use the Sensor underwater.
Do not disassemble, repair, or modify the Sensor.
Always turn OFF the system power before installing or replacing the Sensor.
G-382
System Design
Cables
For both pre-wired and connector models, the maximum tensile force of cables must be 50 N.
Wiring
If the Sensor cables are housed in the same conduit or duct
as for high-voltage and power lines, the Sensor may be subject to induced current, resulting in malfunction or damage.
For this reason, the Sensor cables must be separated from
the high-voltage and power lines or housed in a separate conduit.
Power ON Timing
It takes 100 ms for the Sensor to operate properly after it is
turned ON. Therefore, other devices should be turned ON at
least 100 ms after the Sensor is turned ON. If the Sensor and
the load are connected to different power supplies, the Sensor power must be turned ON first.
Power Supply
When using a commercially available switching regulator, always ground it to the frame ground (FG) or ground (G) terminal. Otherwise, switching noise may result in malfunctions.
Mutual Interference Attenuating Function
1. Two Sets of Sensors:
Set these Sensors to different frequencies with the frequency selector. Refer to DIP Switch 1 Mode Switching
later in this datasheet.
If the mutual interference attenuating function is not used,
and there are two Sensors with the same frequency setting, a beam from the Emitter of one Sensor may hit the
Receiver of the other Sensor, resulting in malfunction.
This function cannot prevent mutual interference between
the F3W-D Sensor and a Photoelectric Sensor of another
model.
2. Three or More Sets of Sensors:
When 3 or more sets of Sensors are used in parallel, mutual interference may result in malfunction. Take the following measures to prevent mutual interference, and
check for mutual interference.
• While in LONG mode, the Sensors are more easily affected by interference. Therefore, if the distance between the Emitter and Receiver of a Sensor is 1 m or
less, use the SHORT mode.
• The distance between two adjacent sets of Sensors
must be at least l1 or l2, which does not cause mutual interference between two Sensors with the same frequency setting. l1 or l2 is at least 1.5 times the distance shown
in Parallel Operating Range of the Engineering Data.
Safety Sensors / Components
Receivers
Vertical Installation
Emitter
Horizontal Installation
Receiver
Emitter
Receiver
DIP switch 1
1
2
Emitter
2
Receiver
Distance X
Emitter
1
Receiver
Distance X
• Install a barrier so that there will not be mutual interference between Sensors with the same frequency setting.
(See Figure 1.)
A light reflection from the wall or floor may go around a
barrier and reach the Receivers. Install a barrier so that
it will also block any light reflection. (See Figure 2.)
Figure 1
Emitter
Figure 2
Receiver
Correct
Emitter
OFF (left)
(See note 3.)
3
Picking indicator flash- SLOW
ing speed setting (see
note 1)
FAST
4
Output mode setting
Light-ON
5
Sensing distance (sen- LONG
SHORT
sitivity) setting
mode (1 to mode (0.05
3 m)
to 1 m)
6
Not used
Emitter
Receiver
Emitter
DIP switch 1 Pin 1
Pin 2
OFF
OFF
ON
OFF
Display mode
All lighting
(All six indicators are lit.)
OFF
Emitter
ON
Receiver
All flashing
Emitter
Elevator-like lighting
(Two adjacent indicators
simultaneously light so that
lighting moves up and
down.)
ON
Wall
Receiver
---
Note: 1 . The flashing speed can be changed in picking display mode (all flashing, elevator-like lighting, or accordion-like lighting) or in external picking display mode. The flashing speed varies with each display mode.
2 . Mutual Interruption Attenuating Function:
The frequency selector is used to switch the emitting frequency between A and B. Making the emitting frequencies of two Sensors different prevents malfunction caused by mutual interference.
3 . Picking Display Mode Setting of DIP Switch 1
ON
Incorrect
Dark-ON
---
Baffle
Baffle
ON (right)
(All six indicators flash
simultaneously.)
Wall
Receiver
Function
Picking display mode
setting
Accordion-like lighting
(Some or all indicators
simultaneously light so
that lighting moves like
an accordion.)
Receiver
Elevator-like Lighting Mode
Baffle
Display progress
Not lit
Lit
Correct Use
DIP Switch 1 Mode Switching
Emitters
1
2
Function
OFF (left)
Picking display mode
setting
(See note 3.)
Accordion-like Lighting Mode
Display progress
3
Picking indicator flash- SLOW
ing speed setting
(see note 1)
FAST
4
External picking display mode setting
(see note 4)
Flashing
Lit
4 . For F3W-D052jP-L Emitters only
5
NC
---
6
Frequency setting
Frequency Frequency
A
B
(see note 2)
F3W-D
ON (right)
---
Wiring
Before turning ON the power, make sure that the supply voltage is within the maximum allowable voltage range.
Always connect the sync lines.
Extension cables must be 0.3 mm2 or more in cross-sectional
area and 100 m or less in length (for the F3W-D052A(P) and
F3W-D052B(P) only).
Be very careful not to get metal chips in the connector especially during wiring.
Incorrect wiring may damage the equipment. Make sure that
the cable length and routing are appropriate to prevent the
connectors and cables from getting disconnected.
G-383
F3W-D
DIP switch 1
Always leave the operation cover closed during operation.
Applying excessive force to the mode selector switch may result in damage. Do not apply a force of more than 5 N.
Cables
Make sure that the bending radius is 25 mm or more.
Installation
Install the Sensor so that its sensing face will not receive light
from the sun, fluorescent lamps, incandescent lamps, and
other light sources.
Do not strike the Sensor with a hammer or any other tool during the installation, otherwise the internal circuitry of the Sensor may be damaged.
Install the Emitter and Receiver in the same orientation as
shown in the following figure. (The cable pullout direction must
be the same.)
Correct
Emitter
Incorrect
Receiver
Emitter
Receiver
Use M4 screws to secure the Sensor body.
Secure the case to a tightening torque of 1.2 N×m or less.
Reflection from Wall or Floor
If the Emitter and Receiver are installed as shown in the following illustration, all the axes may not be interrupted due to
light reflection from the floor or wall. Make sure that the Emitter and Receiver detect the sensing object properly before using the F3W-D in actual operation.
Side View
Operation and Stability Status Display
The following illustration shows the indicator status corresponding to each incident level.
Install the Receiver so that the green stability indicators are
both ON in light receiving status.
Stability indi
cator (green)
Amount of
light received
Stable light-re
ceiving zone
(see note)
Unstable
light-receiv
ing zone
Light-shielded
zone
Operation indicator
(orange)
L-ON
D-ON
ON
OFF
OFF
ON
ON
Operating level
x 1.2
Operating level
OFF
Note: If the Receiver is set to the stable light-receiving zone, it will become
more resistant to environmental fluctuations such as temperature, voltage, dust, and setting deviation after installation. For applications where
a stable light-receiving zone is not obtained, attention must be paid to environmental fluctuations.
Installation Environment
Do not install the F3W-D Sensor under the following conditions.
· Where direct sunlight is received
· Where humidity is high and there is a risk of condensation
· Where there are corrosive gases
· Where vibration and shock are directly transmitted to the
Sensor
Cleaning
· Do not use organic solvents for cleaning. Otherwise, the
surfaces of the Sensor will be eroded.
· Use a soft, dry cleaning cloth.
Top View
Wall
Sensing object
Floor
Emitter
Receiver
Light reflection
M12 Connectors
Always turn OFF the power before connecting or disconnecting an M12 connector.
Always connect or disconnect an M12 connector by holding its
cover.
Always tighten the fixture by hand. Using pliers may result in
damage.
Insufficient tightening may loosen the connector due to vibration, resulting in failure to ensure the specified degree of protection.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. F048-E2-01-X
G-384
In the interest of product improvement, specifications are subject to change without notice.
Safety Sensors / Components
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if
specified) from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS, OR COMMERCIAL
LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR
STRICT LIABILITY.
In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the product.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
• Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
• Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety
equipment, and installations subject to separate industry or government regulations.
• Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix
or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased product.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
ERRORS AND OMISSIONS
The information in this catalog has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent
the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
COPYRIGHT AND COPY PERMISSION
This catalog shall not be copied for sales or promotions without permission.
This catalog is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or reproducing this
catalog in any manner, for any other purpose. If copying or transmitting this catalog to another, please copy or transmit it in its entirety.
Cat. No. F048-E2-01-X
OMRON Corporation
2007. 3
In the interest of product improvement, specifications are subject to change without notice.
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2007 All Rights Reserved.